Self Regulating Heating Cable

  • Pipes Heating Cable Self regulating Heating Trace cable
  • Pipes Heating Cable Self regulating Heating Trace cable
Pipes Heating Cable Self regulating Heating Trace cablePipes Heating Cable Self regulating Heating Trace cable

Pipes Heating Cable Self regulating Heating Trace cable

  • Pipes Heating Cable Self regulating Heating Trace cable
  • Product description: Since Pipes Heating Cable Self regulating Heating Trace cable as an effective fire control pipe antifreeze solution, are widely used in fire fighting pipeline system, its working principle is through
  • INQUIRY
Since Pipes Heating Cable Self regulating Heating Trace cable as an effective fire control pipe antifreeze solution, are widely used in fire fighting pipeline system, its working principle is through the heat coming from the electric tracing band, directly or indirectly heat compensation by heating pipe heat loss, in order to achieve freeze protection requirement, ensure the normal order of the fire pipe in cold winter. Fire special tropical band, with long service life, small starting current, good memory performance, low annual attenuation rate.
Pipes Heating Cable Self regulating Heating Trace cable index
1. Temperature range:
-- operating temperature 65±5℃;
-- surface temperature 85℃;
-- temperature: modified polyolefin 105℃, flame retarding polyolefin 105℃.
2. Construction temperature: -40℃, and the construction temperature is above 0℃
3. Thermal stability: 300 times of on-off and off-off respectively, with the electric tropical heating maintained at more than 90%.
Bending radius: 25.4mm at 20℃ and 35.0mm at -30℃.
Electrical tracing cable installation method
1. The electric heating belt should be attached to the pipe or wound on the pipe. Use aluminum tape to fix the electric heating belt radially with heat-resistant tape at intervals of 0.5-0.8m. Electric tracing cables laid in parallel with the pipeline are generally installed below the pipeline and present a 45-degree Angle to the horizontal axis of the pipeline cross section. If two electric tracing cables are used, they should be laid symmetrically.
2. The minimum bending radius shall not be less than 5-6 times of the thickness of the electric heating belt during installation.
3, when wiring, the electrical tropics and accessories should be correctly and reliably connected, beware of short circuit. At the same time, the braided network is connected with reliable grounding.

4. Burr and sharp Angle should be removed from the surface of pipes or containers to avoid damage to the heat tracing cable during installation. Rustproof coating to dry, electric heating insulation resistance should be 20 or more m Ω (1000 VDC). Do not forcefully pull the electric heating belt. Avoid putting feet or heavy objects on the heating belt. The type of electric heating belt and all accessories shall be consistent with the design requirements.

Pipes Heating Cable